Starting the main engine from the engine control room
CHIEF. LEARN · Guide 3 of 7
Stand by, control to the ECR, the pumps that must run, and answering the telegraph from DEAD SLOW AHEAD to HALF AHEAD, as in the ECR trainer.
The example throughout is the engine control room of a Supramax bulk carrier: three diesel generators on a 440 V, 60 Hz main switchboard with a bus-tie and a power management system, an emergency generator feeding the emergency switchboard, the main engine controlled from the ECR console, and a UV ballast water treatment system.
- ECR
- engine control room
- RCS
- remote control system of the main engine
- FWE
- finished with engines
- ME
- main engine
- FW
- fresh water
Who has control
The main engine can be controlled from the bridge, from the ECR or locally at the engine. Only one place has control at a time, and the change is made on the RCS panel. In the trainer the scenario starts with the engine stopped, the sub-telegraph at FWE and control on the bridge.
The sub-telegraph tells the engine room what to expect: FWE, finished with engines; STAND BY, manoeuvring is coming; and the order for full sea speed when the manoeuvring is over.
Before the first start
The engine needs lubricating oil and cooling water before it turns. In the trainer the start is refused until an ME LO pump and an ME jacket FW pump are running.
On board the checklist is longer and it is your company’s and the engine maker’s: the turning gear out, the starting air receivers charged, the fuel oil system circulating at the right temperature, and after a long stop a slow turn of the engine with the indicator cocks open.
Step by step
- Put the sub-telegraph to STAND BY with the white STAND BY button on the RCS panel.
- Take control to the ECR with the blue ECR button on the RCS panel.
- Start an ME LO pump from group starter panel GSP1 or GSP2.
- Start an ME jacket FW pump from GSP1 or GSP2.
- Move the telegraph lever one step ahead, to DEAD SLOW AHEAD, and watch the actual rpm on the RCS screen rise above 20.
- Move the lever to HALF AHEAD and wait until the actual rpm equals the commanded rpm.
Answering the telegraph
With control in the ECR, the lever on the console is both the answer to the bridge and the order to the engine. Move it step by step and watch the actual rpm follow the command before the next step.
Tell the bridge when you take control and when you hand it back. A misunderstanding about who has control is a common start of a manoeuvring incident.
Check yourself
The engine will not start from the ECR. Which pumps do you check first?
- The ME LO pump and the ME jacket FW pump — correct
- The ballast pumps
- The fire pumps
No lubricating oil and no cooling water, no start. The trainer blocks the start until both are running, as an engine safety system would.
What does STAND BY on the sub-telegraph tell the engine room?
- Manoeuvring is coming: be ready to answer the telegraph — correct
- The engine is finished with
- Full sea speed
STAND BY is the warning that engine orders are coming. FWE means finished with engines.
For training only. The room, the switchboard and the sequences are simplified; class rules, the makers’ manuals and your company’s procedures are the authority.